Yuchai YC16VCG-2000N5LC natural gas generator, 2,000 kW

Natural gas generator set: 2,000 kW / 2,500 kVA, Yuchai YC16VC3300N-D30 gas engine at 1,500 rpm. Supply, installation, commissioning and service in Russia.

Yuchai YC16VCG-2000N5LC gas genset, general view
2,000 kW
rated power, 2,500 kVA
57,900,000 RUB
open frame, incl. VAT
547.6 m³/h
gas at full load
12 mo
warranty from commissioning

The YC16VCG-2000N5LC runs on the Yuchai YC16VC3300N-D30 gas engine, a V16 unit at 1,500 rpm, and gives 2,000 kW / 2,500 kVA at 0.4 kV, 50 Hz. This size suits large energy centers with a steady base load.

At full load it uses 547.6 m³ of gas per hour, about 0.27 m³ per kWh. Hours to major overhaul: 40,000 operating hours according to the factory.

Price and configurations

Open frame
57,900,000 RUB incl. VAT≈ $704,800

For a machine hall or an existing building. The site price: genset only, excluding canopy and commissioning.

Canopy or container
Quoted for your project

Quoted for your project together with delivery and commissioning.

Prices are for the genset on an open frame, incl. VAT, excluding canopy, delivery and commissioning. That is about 29,000 RUB per kW of rated power for the open frame. ≈ $ at the Central Bank of Russia rate of 82.15 RUB/USD as of Nov 14, 2026. Contracts and payments in RUB.

Specifications

Generator set
ModelYC16VCG-2000N5LC
Rated power2,000 kW / 2,500 kVA
Voltage, frequency0.4 kV (on request 10.5 kV, version N5HC), 50 Hz, cos φ 0.8
Rated current3,608 A
Speed1,500 rpm
Electrical efficiency40%
Gas consumption at 100% load547.6 m³/h (at a heating value of 9.13 kWh/m³)
Noise level≤114 dB(A) at 1 m, open frame
Startingelectric starter
Engine
ModelYC16VC3300N-D30
Engine power2,205 kW
Cylinders16, V-type
Bore × stroke200 × 210 mm
Displacement105.6 L
Compression ratio12.5:1
Controllerelectronic (ECU)
Lube oil consumption≤0.5 g/kWh
Hours to major overhaul40,000 operating hours
Alternator
ModelYC-2000-4L
Voltage regulationAVR
Protection ratingIP23
Insulation classH
Gas
Fuelnatural gas, methane from 85%
Gas inlet pressure15–30 kPa
Heat recovery
Jacket water heat (HT circuit)1,439 kW
Exhaust heat (cooled to 120 °C)1,106 kW
Total heat outputup to 2,545 kW
Dimensions and weight
L × W × H, open frame8,416 × 2,055 × 2,890 mm
Weight, open frame24,800 kg

Specifications are the manufacturer's data. 50 Hz units: the output is 0.4 kV (medium voltage on request). We send a full English specification on request.

Photos

Yuchai YC16VCG-2000N5LC gas genset, general view
Yuchai YC16VCG-2000N5LC gas genset, general view
Yuchai YC16VCG-2000N5LC gas genset, dimension drawing
Yuchai YC16VCG-2000N5LC gas genset, dimension drawing
Yuchai gas genset, container configuration (example from the same series)
Yuchai gas genset, container configuration (example from the same series)
Yuchai gas genset, open frame (example from the same series)
Yuchai gas genset, open frame (example from the same series)

For Bitcoin mining

1,700 kW for a 24/7 load

For round-the-clock operation plan on about 85% of rated power: this is how hours to overhaul are counted.

About 485 ASICs

Air-cooled machines drawing about 3.5 kW each, with headroom for container ventilation and auxiliary load.

≈ 2.19 RUB/kWh for fuel

Example at a gas price of 8 RUB/m³: 0.27 m³ per kWh, without oil and service. Your figure depends on your gas price.

Estimates for planning, not a guarantee. More on sizing: gas generators for Bitcoin mining. Prefer not to run a genset yourself? Host your ASICs on our own gas power: gas-powered Bitcoin mining hosting.

Warranty, lead time and service

Warranty

12 months from commissioning.

Lead time

45–100 days from order.

Service

Scheduled maintenance by the factory schedule, 40,000 operating hours to major overhaul. Service under contract by our team in Russia.

Compare and choose

Case studies and articles

Questions

How much does the Yuchai YC16VCG-2000N5LC cost?

57,900,000 RUB incl. VAT for the genset on an open frame, excluding canopy and commissioning. Delivery is quoted from the site address.

How much gas does the YC16VCG-2000N5LC use?

547.6 m³ per hour at full load. Size the gas supply on full-load consumption, not on the average: a lack of volume or pressure shows up under load.

How many ASIC miners can the YC16VCG-2000N5LC power?

About 485 air-cooled ASICs drawing about 3.5 kW each, counting on about 1,700 kW of 24/7 load (85% of rated power).

What is the warranty and lead time for the YC16VCG-2000N5LC?

Warranty: 12 months from commissioning. Lead time: 45–100 days. Service under contract is done by our team in Russia.

Is the YC16VCG-2000N5LC available in a canopy or a container?

The price is for the open frame. A canopy or a container is quoted for your project together with delivery and commissioning.

Talk to the team

We answer in English. Tell us what you are looking for (hosting, equipment or an investment) and we will come back with numbers, documents and, if you wish, a video tour or a site visit.

What do you need?
Prefer email? Write to fastminesales@gmail.com.